Volt-ampere : ウィキペディア英語版
A volt-ampere (VA) is the unit used for the apparent power in an electrical circuit, equal to the product of root-mean-square (RMS) voltage and RMS current.Ciletti, M. D., Irwin, J. D., Kraus, A. D., Balabanian, N., Bickard, T. A., and Chan, S. P. (1993). Linear circuit analysis. In ''Electrical Engineering Handbook,'' edited by R. C. Dorf. Boca Raton: CRC Press. (pp.82–87) In direct current (DC) circuits, this product is equal to the real power (active power) ''IEEE 100 : the authoritative dictionary of IEEE standards terms.-7th ed.'' ISBN 0-7381-2601-2, page 23 in watts. Volt-amperes are useful only in the context of alternating current (AC) circuits (sinusoidal voltages and currents of the same frequency).Some devices, including uninterruptible power supplies (UPSs), have ratings both for maximum volt-amperes and maximum watts. The VA rating is limited by the maximum permissible current, and the watt rating by the power-handling capacity of the device. When a UPS powers equipment which presents a reactive load with a low power factor, neither limit may safely be exceeded.(''Watt Ratings Differs From Volt Amp Ratings'' ) APC For example, a (large) UPS system rated to deliver 400,000 volt-amperes at 220 volts can deliver a current of 1818 amperes.The volt-ampere is not an SI unit. This is because even if reactive or apparent, the quantity the unit represents is power, and SI is a coherent system that does not use different units for the same quantity in different contexts.(SI Brochure, 8th ed. ): "Just as the quantity symbol should not imply any particular choice of unit, the unit symbol should not be used to provide specific information about the quantity ()" Section 5.3.2.== See also ==* AC power* Power factor* Volt-ampere reactive

A volt-ampere (VA) is the unit used for the apparent power in an electrical circuit, equal to the product of root-mean-square (RMS) voltage and RMS current.〔Ciletti, M. D., Irwin, J. D., Kraus, A. D., Balabanian, N., Bickard, T. A., and Chan, S. P. (1993). Linear circuit analysis. In ''Electrical Engineering Handbook,'' edited by R. C. Dorf. Boca Raton: CRC Press. (pp.82–87)〕 In direct current (DC) circuits, this product is equal to the real power (active power) 〔''IEEE 100 : the authoritative dictionary of IEEE standards terms.-7th ed.'' ISBN 0-7381-2601-2, page 23〕 in watts. Volt-amperes are useful only in the context of alternating current (AC) circuits (sinusoidal voltages and currents of the same frequency).
Some devices, including uninterruptible power supplies (UPSs), have ratings both for maximum volt-amperes and maximum watts. The VA rating is limited by the maximum permissible current, and the watt rating by the power-handling capacity of the device. When a UPS powers equipment which presents a reactive load with a low power factor, neither limit may safely be exceeded.〔(''Watt Ratings Differs From Volt Amp Ratings'' ) APC〕 For example, a (large) UPS system rated to deliver 400,000 volt-amperes at 220 volts can deliver a current of 1818 amperes.
The volt-ampere is not an SI unit. This is because even if reactive or apparent, the quantity the unit represents is power, and SI is a coherent system that does not use different units for the same quantity in different contexts.〔(SI Brochure, 8th ed. ): "Just as the quantity symbol should not imply any particular choice of unit, the unit symbol should not be used to provide specific information about the quantity ()" Section 5.3.2.〕
== See also ==

* AC power
* Power factor
* Volt-ampere reactive

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「A volt-ampere (VA) is the unit used for the apparent power in an electrical circuit, equal to the product of root-mean-square (RMS) voltage and RMS current.Ciletti, M. D., Irwin, J. D., Kraus, A. D., Balabanian, N., Bickard, T. A., and Chan, S. P. (1993). Linear circuit analysis. In ''Electrical Engineering Handbook,'' edited by R. C. Dorf. Boca Raton: CRC Press. (pp.82–87) In direct current (DC) circuits, this product is equal to the real power (active power) ''IEEE 100 : the authoritative dictionary of IEEE standards terms.-7th ed.'' ISBN 0-7381-2601-2, page 23 in watts. Volt-amperes are useful only in the context of alternating current (AC) circuits (sinusoidal voltages and currents of the same frequency).Some devices, including uninterruptible power supplies (UPSs), have ratings both for maximum volt-amperes and maximum watts. The VA rating is limited by the maximum permissible current, and the watt rating by the power-handling capacity of the device. When a UPS powers equipment which presents a reactive load with a low power factor, neither limit may safely be exceeded.(''Watt Ratings Differs From Volt Amp Ratings'' ) APC For example, a (large) UPS system rated to deliver 400,000 volt-amperes at 220 volts can deliver a current of 1818 amperes.The volt-ampere is not an SI unit. This is because even if reactive or apparent, the quantity the unit represents is power, and SI is a coherent system that does not use different units for the same quantity in different contexts.(SI Brochure, 8th ed. ): "Just as the quantity symbol should not imply any particular choice of unit, the unit symbol should not be used to provide specific information about the quantity ()" Section 5.3.2.== See also ==* AC power* Power factor* Volt-ampere reactive」の詳細全文を読む